Tanujaya, Harto COOLING EFFECT OF CAPILLARY TUBE IN REFRIGERATOR. COOLING EFFECT OF CAPILLARY TUBE IN REFRIGERATOR.
Text
23a_Artikel_ICET_First_2013_Prosiding.pdf Download (910kB) |
Abstract
Capillary tube is one of the throttling device in the refrigeration such as a small refrigerator. In this research, the capillary tube is made of a copper tube with internal diameter of 0.0063 m and the length of 0.248 m. Performance of the refrigerator can be influenced by shape and dimension of the capillary tube. Precooling around the capillary tube is expected increase the performance of the refrigerator. Refrigerant 22 is used in the experiment. The highest and lowest of the Coefficient of Performance (COP) of the refrigerator are investigated at position F 11 and F .